Achievers Automation Limited

Manufacturer from China
Verified Supplier
1 Years
Home / Products / Pepperl Fuchs Safety Barrier /

16 Channel IP20 Pepperl Fuchs Safety Barrier HART MUX Primary Module KFD2-HMM-16

Contact Now
Achievers Automation Limited
Visit Website
City:hong kong
Country/Region:china
Contact Person:MsJoanna Yang
Contact Now

16 Channel IP20 Pepperl Fuchs Safety Barrier HART MUX Primary Module KFD2-HMM-16

Ask Latest Price
Video Channel
Brand Name :PEPPERL FUCHS
Model Number :KFD2-HMM-16
Place of Origin :Germany
MOQ :1
Price :Negotiable
Payment Terms :T/T
Supply Ability :100pcs per month
Delivery Time :Negotiable
Packaging Details :carton
Manufacturer :PEPPERL FUCHS
Product No :KFD2-HMM-16
Labeling :space for labeling at the front
Degree of protection :IP20
Connection :screw terminals
Mass :approx. 250 g
Control elements :DIP switch
Type :RS-485 , 2-wire multidrop
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

PEPPERL FUCHS HART MUX Primary Module KFD2-HMM-16 16-channel

Product Description
HART MUX Primary Module
Functional safety related parameters
Safety Integrity Level (SIL) SIL 3
Supply
Connection terminals 17+, 18-
Rated voltage 20 ... 32 V DC typical at 100 mA
Power consumption max. 3 W
HART signal channels (non-intrinsically safe)
Conformity HART field device input (revision 5 to 7)
Connection 26-pin flat cable for analog connections
14-pin flat cable for primary module/secondary module connection between KFD2-HMM-16 and KFD0-HMS-16
Leakage current < 3 µA at -20 ... 85 °C (-4 ... 185 °F)
Terminating resistor external 230 ... 500 Ω standard (up to 1000 Ω possible)
Output voltage ≥ 400 mV ss (with the terminator resistance specified above)
Output resistance 100 Ω or smaller, capacitive coupling
Input impedance according to HART specification
Input voltage range 0.08 ... 4 V ss ; typ. ± 5.2 V as local reference
Interface
Transfer rate 9600, 19200, or 38400 Bit/s (selectable with DIL switch (2 and 3) by the user)
Type RS-485 , 2-wire multidrop
Address selection One of 31 possible addresses selectable per DIL switch (4 ... 8)
Indicators/settings
Control elements DIP switch
Configuration via DIP switches
Labeling space for labeling at the front
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EU EN 61326-1:2013 (industrial locations)
Conformity
Degree of protection IEC 60529:2001
Ambient conditions
Ambient temperature -20 ... 60 °C (-4 ... 140 °F)

16 Channel IP20 Pepperl Fuchs Safety Barrier HART MUX Primary Module KFD2-HMM-16